Process setting

Gate freeze study: set holding time with a scale, not by guesswork

Holding time adds material to the part until the gate freezes; after that it is wasted seconds. The steps for finding the right time by plotting part weight against holding time, and how to read the result.

November 4, 2026 · 4 min read

The robotic engineer1 · CC BY-SA 4.0 · Wikimedia Commons · cropped

The job of the holding (packing) phase is to add material to a part that is cooling and shrinking. This is only possible while the gate is open. Once the gate has frozen, holding pressure cannot add anything to the cavity; the machine only presses on the runner and the screw. If holding ends before the gate freezes, melt flows back out of the cavity and sink marks and dimensional variation begin. If it is longer than needed, the cycle is extended for nothing.

The most reliable way to find the right time is simple: weigh the part.

Preparation

  • The process should be stable: mold and melt temperatures settled and at least 15–20 good shots taken.
  • The filling phase (speed, V/P switchover) and the holding pressure stay constant at production values. Only the holding time changes in the test.
  • Increase the cooling time so that the total cycle stays constant as holding time is shortened. This way the time the part spends in the mold does not change, and any weight difference comes from holding alone.
  • Use a scale with 0.01 g resolution; for small parts 0.001 g is better.
  • With a cold runner, cut off the runner and weigh only the part. In a multi-cavity mold, weighing each cavity separately also shows any imbalance between cavities.

Steps

  1. Start holding time at a very short value (for example 0.5–1 s).
  2. Increase it by 0.5–1 s at each step. Smaller steps suit thin parts with small gates; larger steps suit thick parts.
  3. At each step let a few shots stabilize, then weigh 3–5 parts and take the average.
  4. Continue until the weight no longer increases, then take 2–3 more steps.
  5. Plot weight against holding time.

Reading the graph

The typical curve rises quickly at first and then levels off. The point where it levels off is the gate freeze time. Every second added after this point adds nothing to the part.

For production, set holding time slightly above the freeze time. Common practice is a safety margin of freeze time + 10–20% or +0.5–1 s. This margin keeps the gate frozen through small variations in material lot and mold temperature.

An example:

Holding time (s)Average weight (g)
141.82
242.35
342.71
442.88
542.90
642.90

The weight levels off between 4 and 5 seconds. The freeze time is about 4.5 s, so 5–5.5 s is a reasonable production holding time.

If the curve does not level off

  • Hot runner or thermal (open) gate: the gate does not freeze and the weight keeps rising for a long time. Here choose holding time based on freezing of the part's own thick section, or on the dimensional and sink criteria. With a valve gate, holding is ended by the valve pin closing; the test is used to set the valve closing time.
  • Gate too large or part too thick: the freeze time can be long enough to dominate the cycle. At the design stage, check the ratio of gate cross-section to wall thickness. See Gate types and gate location
  • Weight drops after a certain point: the cushion may be reaching zero during holding; the screw has bottomed out and the pressure no longer reaches the part. Increase the shot size and check the check ring for leakage.
  • Weight scatters widely from shot to shot: stabilize the process first. If the cushion, melt temperature or mold coolant fluctuate, the test will not give a meaningful result.

When to repeat it

Gate freeze time depends on the material, the mold temperature and the condition of the gate. Repeat the test:

  • When the material grade or supplier changes,
  • When mold or melt temperature changes significantly,
  • When the gate has been reworked or is worn,
  • When the mold is moved to another machine.

Recording the freeze time and the production holding time in the mold log lets you start from the same point at the next mold setup. For the holding pressure itself and the V/P switchover, see V/P switchover and holding settings. For where the test fits in a complete setup method, see What is scientific molding?

Is something missing or wrong in this article? .

You might also be interested in

All articles →