Latest in the forum:Plast Eurasia 2026'ya gidiyor musunuz? Fuarda neye bakacaksınız?Join the forum →
Calculation

Mold cooling water flow rate: how many litres per minute do you need, from the Reynolds number and the heat balance?

A cooling channel only works well when the water flows turbulently. Steps and an example for calculating the minimum flow per circuit with the Reynolds number and the total flow with the heat balance, by channel diameter and water temperature.

November 5, 2026 · 5 min read

Jacek Halicki · CC BY-SA 4.0 · Wikimedia Commons · cropped

Water circulating through a mold does not mean the mold is being cooled. If the water flows slowly in smooth layers (laminar flow), the water near the channel wall heats up and stays there, and heat transfer drops several times. Good cooling needs turbulent flow. The way to check this is the Reynolds number.

The Reynolds number

The Reynolds number (Re) is a dimensionless number that shows whether the flow is laminar or turbulent:

Re = v × d / ν

  • v: mean water velocity in the channel (m/s)
  • d: channel diameter (m)
  • ν: kinematic viscosity of water (m²/s)

Interpretation:

  • Re < 2,300: laminar, poor cooling.
  • 2,300–4,000: transition zone, unstable.
  • Re > 4,000: turbulent. A common target in mold cooling is Re ≥ 10,000; going higher adds less heat transfer but quickly increases pump load and pressure drop.

Water viscosity falls with temperature

Water temperatureν (×10⁻⁶ m²/s)
10 °C1.31
20 °C1.00
30 °C0.80
40 °C0.66
60 °C0.47
80 °C0.36

Cold water is more viscous and needs a higher velocity for the same turbulence. 10 °C chiller water needs about twice the flow of 40 °C tower water.

Minimum flow per circuit

Since flow Q = v × A and A = π × d² / 4, the minimum flow for a target Reynolds number is:

Q_min = Re × ν × π × d / 4

To convert the result (m³/s) to litres per minute, multiply by 60,000.

Example, Re = 10,000 and water at 30 °C (ν = 0.80 × 10⁻⁶ m²/s):

Channel diameterRequired velocityMinimum flow
8 mm1.00 m/s≈ 3.0 L/min
10 mm0.80 m/s≈ 3.8 L/min
12 mm0.67 m/s≈ 4.5 L/min
14 mm0.57 m/s≈ 5.3 L/min

Note: the required flow rises in proportion to the diameter, while the required velocity falls as the diameter grows. These values are per circuit. For circuits in parallel, multiply by the number of circuits; in channels connected in series the same water passes through all of them.

Total flow: the heat balance

The Reynolds number only tells you whether the flow is turbulent. Whether the water can carry away the heat of the part is shown by the heat balance.

  1. Heat entering the mold: P ≈ (shot weight / cycle time) × Δh

Δh is the heat the material releases from melt temperature down to ejection temperature (enthalpy difference). For semi-crystalline materials it is high because the heat of crystallization is included; for PP it is about 500–600 kJ/kg, and lower for amorphous materials such as ABS. Take the exact value from the material's enthalpy curve.

  1. Required water flow: ṁ = P / (c_p × ΔT_water)

For water c_p ≈ 4.18 kJ/(kg·K); 1 kg of water ≈ 1 litre.

  1. Inlet–outlet difference (ΔT_water): the target is 2–3 °C for general parts and ≤ 1 °C for tight-tolerance parts. A larger difference leaves one end of the mold hotter than the other and the part warps.

Example: 200 g shot, 20 s cycle, PP, Δh = 550 kJ/kg.

  • Heat: 0.01 kg/s × 550 kJ/kg = 5.5 kW
  • Water for ΔT = 3 °C: 5.5 / (4.18 × 3) = 0.44 kg/s ≈ 26 L/min in total
  • With 4 parallel circuits of 10 mm diameter: ≈ 6.6 L/min per circuit. This is above the 3.8 L/min needed for turbulence, so both turbulence and the heat balance are satisfied.

If the same mold is connected with 2 circuits, each needs 13 L/min; pressure drop and the pump capacity of the temperature control unit may become the limit.

This calculation assumes all heat goes into the water. In reality part of it goes to the air and the machine platens, so the result is on the safe side.

Common mistakes on the shop floor

  • Quick couplings and narrow fittings: even with a 10 mm channel, a 6 mm fitting limits the flow of the whole circuit.
  • Very long series circuits: the water heats up towards the end of the channel and the outlet side stays hot. Splitting a long circuit and connecting the parts in parallel lowers both ΔT and pressure drop.
  • Scale and rust: over time the channel diameter shrinks and the flow drops. Regular measurement with a flow meter shows the problem before part quality suffers.
  • Glycol mixtures and oil: water-glycol and heat transfer oil are much more viscous than water. The same channel needs a much higher velocity for turbulence; with an oil unit this is often not achievable, so calculate accordingly.
  • Baffles and bubblers: the flow cross-section in these elements is smaller than in the main channel; base the Reynolds calculation on the narrowest section. See Types of cooling channels

For how cooling time changes with wall thickness, see Why cooling time grows with the square of wall thickness. For cycle and cooling calculations, use the calculator.

Is something missing or wrong in this article? .

You might also be interested in

All articles →