Defect guide

Flash

Plastic escapes through the parting line or around the ejector pins.

Also known as: flash, overflow, parting line flash, burr

Symptoms

  • Thin plastic film along the parting line
  • Ring-shaped flash around ejector pins
  • Part weight higher than normal

Tip: Flash is more often caused by the V/P changeover and holding phase than by insufficient clamping force.

Order of solutions

  1. Clean the mold and check the parting surface with blue marking compound
  2. Move the V/P changeover earlier; reduce holding pressure and time
  3. Reduce melt temperature and speed
  4. Calculate the required clamping force and compare it with the machine capacity
  5. Check the vent depth
  6. Have the toolmaker check the mold surface and the platen parallelism

Likely causes

Process setting

  • Holding pressure too high or holding time too long
  • V/P changeover too late; the cavity is overfilled and produces a pressure peak
  • Melt temperature too high, viscosity too low
  • Injection speed too high

Machine

  • Clamping force insufficient or set incorrectly
  • Platen parallelism out of tolerance
  • Tie bars or toggle mechanism worn

Mold

  • Parting surface worn, crushed or dirty
  • Vent channel too deep
  • Foreign matter on the mold contact surfaces

Part design

  • Projected area large compared with the machine clamping force
  • Thin sharp edges on the parting surface

Was this information helpful? If you notice anything missing or wrong, please .

Related articles

Other defects